Vision inspection and measurement that catch bad packs before the case packer.

Fill, seal, cap, count, placement and damage, checked on every pack, with a reject timed to the pack and confirmed when it fires.

Tell us about the system

Problems

What this station catches.

Fill level

Packs and bottles under- or over-filled. See Food and Beverage.

Label placement (360°)

Missing, skewed or wrinkled labels. See Beverage.

Containers

Cracked or dirty empties. See Beverage.

Product appearance

Shape, color, breakage, bloom, and enrobing. See Food.

How it works

How the station checks.

A timed, confirmed reject

The reject is timed to the part and confirmed when it fires.

A record of every reject

Every reject logged with image and lot. See Traceability.

Pass or fail

From picture to reject.

01

Capture

A photo eye or encoder triggers the camera, and a short strobe freezes the moving pack. Filters even out brightness and noise when the check needs it.

02

Locate

The software finds the pack, so the checks land in the right place on a pack that arrives turned or off center.

03

Measure

Pixels become numbers: fill height, piece count, seal width, the size of a mark.

04

Decide

Each number is compared with limits set from real good and bad samples. A fail fires the reject when that unit reaches it, and the image and reason are saved.

05

Rules or deep learning

Rule-based tools suit measurements, counts, and presence, and each reject traces to a limit. Deep learning suits faults that vary in look, such as cosmetic marks and wrinkles, and trains on many labeled pictures. Many stations use both. See How machine vision works.

Measurement

How does machine vision measurement work?

The camera turns edges into numbers, and each number is compared with limits set from real good and bad parts.

Edges

From pixels to millimeters

Edge tools find the part outline to a fraction of a pixel. A calibration target imaged at the same distance converts pixels to millimeters.

Optics

Telecentric or standard lens

A telecentric lens keeps the size constant when the part moves toward or away from the camera. A standard lens needs the part at a fixed distance.

Lighting

Backlight for outlines

A backlight turns the part into a sharp silhouette, the most repeatable way to measure outer dimensions. Front light is used for features on a surface.

Resolution

Pixels across the view

How fine the station can measure depends on the pixels across the field of view. The imaging calculator shows the trade-off for your part.

Dimensions

What can a vision system measure on the line?

Size

Length, width and diameter

Outer dimensions of parts, closures and packs, checked on every unit.

Heights

Cap, fill and seam height

Cap seating height, fill height and can seam height, seen from the side. See fill level and seam inspection.

Position

Placement against a reference

Label placement, print position and part location measured from a reference edge.

Gaps

Gaps, pitch and spacing

Gaps between parts, the pitch of repeated features and spacing in a tray or on a web.

Line speed

What does line speed change for measurement?

Motion

Freeze the part

A short exposure and strobed light keep edges sharp, because blur makes a part look bigger than it is.

Presentation

Tilt and rotation

A part that tilts or turns changes its measured size. Guides, fixturing or software correction keep the view consistent.

Tracking

Encoder-timed reject

An encoder tracks each part from the camera to the reject, so the right part is removed.

Interface

GigE Vision cameras

GigE Vision cameras feed the vision controller, which sends pass or fail to the PLC for every part.

Limits

What can’t machine vision measurement do?

Hidden features

Only what the camera sees

A 2D camera measures the visible outline. Internal dimensions and depth need a 3D sensor, another view or an off-line gauge.

Release checks

Not a lab gauge

Inline measurement checks every part against limits. It supports, and does not replace, the calibrated gauges and lab checks used for release.

Limits

Set from real samples

Limits are set on the HMI from good and bad samples. The study’s test images show how fine the station can measure your part.

FAQ

Questions about machine vision measurement

QHow accurate is machine vision measurement?

It depends on the field of view, the camera resolution, the lens, the light and how the part is presented. The feasibility study measures your sample parts and states in writing what the station can repeat on them.

QCan vision replace calipers or a lab gauge?

For checking visible dimensions on every part on the line, often yes. For internal dimensions or the measurements used to release product, the lab gauge stays. Vision measurement supports those checks and does not replace them.

QDoes the part have to stop to be measured?

Usually not. Strobed light freezes a moving part, and an encoder times the reject. Some fine measurements need the part held still or indexed, which the study tells you.

QCan it measure height, depth or flatness?

A 2D camera measures what shows in its view, such as a cap height seen from the side. Depth, flatness or a surface profile needs a 3D sensor, which the study recommends when the job needs it.

Tell us what keeps going wrong.

Tell us about the system